Designed for Critical Server, Network, AV Systems, Telecommunications Equipment

MAIN FEATURES

• INTEGRATED POWER CONDITIONER
• BUILT-IN POWER FACTOR CORRECTION
• PURE SINE WAVE OUTPUT WITH 0.9 POWER FACTOR
• REAL-TIME VOLTAGE & FREQUENCY REGULATION
• ADJUSTABLE LED DISPLAY

Advanced Overload Protection

  • Multiple overload level detection allows for extended time of uninterrupted operation during various stages of overloading.
  • Automatic switching to BYPASS mode for additional time of uninterrupted operation.

Real-time Network Monitoring and Notifications

  • Remote management and configuration via Web Browser, NMS
  • Event logging to trace the operation’s history
  • Graphic data logging to analyze power conditions
  • Event notifications via Email, SNMP traps
  • It has the ability to set up for an alert when the battery is in need of replacement
  • Supports Environmental Sensor (optional)
    advanced Enterprise power management software
  • Power ON/OFF, reboot, and on demand battery testing for UPS.

RACK OR TOWER CONFIGURATION

EDC LCD Display

LCD Panel

  • Easy-to-read LCD display provides information about power conditions.
  • The LCD display will show how much time is left before the UPS will turn back on or shut down
  • Unit can be controlled via LCD display and via network card web console.
  • LCD can be easily rotated via software.
  • Displays various information in detail, such as load levels in VA or WATT, backup time at current load, battery pack voltage, etc.

OTHER FEATURES

  • Integrated Power Conditioner for Protection against Common Mode, Normal
  • Mode, Ground Loop Interferences
  • High efficiency On-Line double Conversion / pure sine wave output design
  • Fully informative LCD display to show power loads and UPS stats
  • Automatic voltage regulator (AVR and battery backup in one unit)
  • Short circuit and overload protection with automatic bypass capability
  • Power management software with network monitoring capability with diagnostic and battery check
  • Gigabit Network surge protection circuit
  • HID USB and Smart RS232 communications port
  • User replaceable UPS battery
  • UPS can power on with or no batteries
  • SNMP network management capability
  • EPO (Emergency Power Off) capable
  • Two year warranty – Optional extended warranty

Energy-Saving Technology

High Eco Mode Efficiency and Fixed Frequency Conversion Mode

ECO Mode: For sites with stable power, ECO mode will extend battery lifetime and reduce overall current draw.

Conversion Mode: For sites running on a generator, the Fixed Frequency mode will maintain a stable frequency for connected equipment.

 

PROTECTION AGAINST...

SPECIFICATIONS

MODEL

EDC2200RT-T / EDC2200RT-THW

Capacity (VA / Watts)

2200VA / 1980W

Energy-Saving Technology

Yes, ECO Mode Efficiency 95%

INPUT

Input Voltage Range

55~150Vac

Input Frequency Range

50/60Hz

Input Power Factor

0.99

Cold Start

Yes

UPS Inlets

IEC C20/Hard Wire Terminal

OUTPUT

Output Waveform

Pure Sine Wave

Output Voltage

100, 110, 115, 120, 127Vac ±1% *

Output Frequency

50/60Hz (Auto-Sensing or Configurable) ±0.5Hz **

Like Mode Voltage Regulation

±1%

ECO Mod Voltage Regulation

±10%, ±15% (Configurable)

Crest Factor

3:1

Harmonic Distortion

THD < 3% at Linear Load, THD < 6% at Non-linear Load

UPS Outlets

(8) NEMA 5-20R ( (4) Remote Switchable Set) Terminal+(2) NEMA 5-20R

Transfer Time (Typically)

0ms

BATTERY

Model – Voltage

EPO22 – 48VDC (Sealed, Maintenance Free)

Run Time (Half Load)

12 Minutes

Recharge Time (Typically)

4 Hours (inside batteries)

PROTECTION

Power Conditioning

Power Conditioning Protection against Common Mode, Normal Mode, Ground Loop Interferences

  

 

Overload
Protection

 

  

Line Mode

Battery Mode

Bypass Mode

105%~110% Warning, transfer to bypass after 10min; 110%~130% Warning,
transfer to bypass after 1min; >130% Warning, transfer to bypass after 3s.

105%~110% Warning, shut down after 6min; 110%~130% Warning,
shut down after 1min; >130% Warning, shut down after 3s.

110%~120% Warning, shut down after 30min; 120%~130% Warning,
shut down after 10min; >130% Warning, shut down after 1min.

Short Circuit Protection

UPS Output Cut off Immediately or Input Fuse / Circuit Breaker Protection

MANAGEMENT

LCD Screen

Graphic LCD

Connectivity Ports

(1) Serial Port (RS232), (1) USB Port

Emergency Power OFF (EPO)

Yes

Audible Alarms

Battery Mode, Battery Low, Overload, UPS Fault, Replace Battery, Bypass Mode
Charger Failure / Over Charged, Fan failure, EPO active

Power Management Software

PowerMaster

SNMP / HTTP Capable

(1) Expansion Port (With optional card)

ENVIRONMENT

Operating Temperature

0°C to 40C

Operating Relative Humidity

20% to 90% Non-Condensing

PHYSICAL

Dimensions (W x D x H) (in.)

17.24 x 16.93 x 3.46

Net Weight (Lbs.)

44.85

Altitude

<2000m

  Specification are subject to change without notice.

MORE IMAGES

FRONT/REAR PANEL DESCRIPTION

SOFTWARE

PMCARD compatibility with PowerMaster Enterprise enhances UPS monitoring and management. With real time view and mapping for all devices connected with a PMCARD.

  • Monitor all power and environmental conditions in the server room
  • Centralized platform provides real-time remote monitoring
  • Analytical charts and reports to help manager to make optimal decision
  • Real-time alarm notification to reduce downtime

DOWNLOAD DATASHEET

TROUBLESHOOTING

Problem: O/P Overload
Possible Cause: Your equipment requires more power than the UPS can provide. If the UPS is in Line Mode then it will transfer to Bypass Mode; if the UPS is in Battery Mode it will shut down. 
Solutions: Shut off non–essential equipment. If this solves the overload problem, the UPS will transfer to normal operation. 

Problem: Battery Mode
Possible Cause: UPS is operating on battery power.
Solutions: Save your data and perform a controlled-shutdown.

Problem: Battery Low
Possible Cause: UPS is operating on battery power and will be shutting down soon due to extremely low battery voltage.
Solutions: UPS will restart automatically when acceptable
utility power returns.

Problem: BAT Disconnected / Battery Replace 
Possible Cause: Missing battery power.
Solutions: Check battery connector when use battery packages. 

Problem: BAT Disconnected / Battery Replace 
Possible Cause: UPS has failed in Battery Test.
Solutions: Contact technical support to replace the battery.

Problem: Charger Failure
Possible Cause: Charger has failed.
Solutions: 1. Shut down UPS and turn off AC input. 2. Contact Supplier for repair.

Problem: EPO OFF
Possible Cause: Missing the EPO connection.
Solutions: Check the EPO connection.

Problem: Over Temperature
Possible Cause: UPS is operating on battery power.
Solutions: 1. Shut down UPS. Restart UPS to Check the fan for
operation and if the ventilation hole has been covered.  2. Contact supplier for repair.

Problem: Output Short
Possible Cause: Output short circuit.
Solutions: 1. Shut down UPS.  2. Your attached equipment may have problems, please remove them and check again.

Problem: High O/P V
Possible Cause: Output voltage is too high.
Solutions: 1. Shut down UPS. 2. Contact supplier for repair.

Problem: Low O/P V
Possible Cause: Output voltage is too low. 
Solutions: 1. Shut down UPS. 2. Contact supplier for repair.

Problem: Bus Fault
Possible Cause: Internal DC bus voltage is too high or too low.
Solutions: 1. Shut down UPS. 2. Contact supplier for repair.

Problem: Startup fail
Possible Cause: High temperature , or fan fail, or battery low, or EPO off.
Solutions: 1. Restart UPS and press the “DOWN” button to view the warning event. Then refer to the solution for the warning. 2. Contact supplier for repair.

CONNECTED EQUIPMENT PROTECTION POLICY

At Emerge Power Solutions, we stand behind the quality and reliability of our power protection products. That is why we offer comprehensive $25,000 Connected Equipment Protection Policy. If the Emerge Power Solutions equipment fails and this failure allows a surge to pass through and damage the connected equipment, Emerge Power Solutions will pay for the repair or replacement of the connected equipment in accordance to our Connected Equipment Protection Policy. Click here for additional details on our Connected Equipment Protection Policy.

also available

Office Plus UPS (Standby)
Battery backup with electronic power conditioner

Office Plus - Stand by UPS
MORE

Venus Plus (SBP) UPS (Line Interactive)
Battery backup with electronic power conditioner
and automatic voltage regulator.

MORE

iPCS Isolated Power Control Station
Pure sine wave output, switchable receptacles, electronic power conditioner and power distribution control.

MORE

Learn how to avoid power problems and save thousands